Hubbell Electric Heater Company J User Manual Page 28

  • Download
  • Add to my manuals
  • Print
  • Page
    / 31
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 27
28
SENSOR PROBE
1. Disconnect power from unit.
2. Shut off incoming water supply.
3. Attach hose to drain connection.
4. Lift manual release lever on relief valve to let air into system or break union on outgoing water line.
5. Drain water from tank.
6. Disconnect probe wire from control board. (See picture)
Probe connection (J3)
7. Remove probe from tank using a 13/16” slotted socket or 13/16” spark plug wrench to accommodate
the probe cable.
NOTE: Care should be taken not to pull or put excessive force on the cable to probe connection.
8. Install new #115 Buna-N o-ring gasket and
install new probe. NOTE: Hubbell
recommends lubricating the o-ring with Parker
O-Lube prior to installation. WARNING: Do
not remove the jam nut. To replace the probe,
remove the entire probe assembly from the
tank.
Probe
9. Reconnect probe wire to control board.
10. Refill tank.
11. Check for leaks. Retighten as required.
12. Note that to resume operation the controller will need to be reset by pressing the ‘RESET’ button on
the display.
CAUTION: Do not use plumber’s tape/Teflon tape/pipe dope when installing the probe. Tape will prevent
the low water detection system from operating properly and will cause false low water errors. Lubricate O-
ring prior to installation.
Tighten probe at the brass hex flats only. Use a 13/16” open ended socket or spark plug wrench. Do not
apply pressure, twist, or turn the black wire or the stainless steel jam nut, as this will damage the probe.