SECTION IV – TROUBLESHOOTING
Symptom Probable Cause Corrective Action / Remedy
Circuit breaker tripped at source. Reset circuit breaker.
High limit switch tripped. Reset high limit switch.
Loose wires. Tighten wires. Torque screws per torque
chart included in Section VI.
Heating element inoperable. Check heating element operation by
clamping an Amprobe around each wire to
the element. The ampere reading should
agree with the nameplate ‘AMP’ figure.
Low line voltage. Have source electrical system checked by
an electrician.
Faulty thermostat. Move thermostat dial through full range. A
definite ‘click’ should be heard. If not,
replace thermostat.
No hot water
Faulty low water cut-off, if
installed.
Check to see if tank is full of water. If not,
fill tank. If problem continues and tank is
full, check for continuity between the
common and normally open contact of the
relay board. If continuity is not observed,
replace low water cut-off.
Faulty thermostat. Check thermostat adjustment. Monitor
thermostat as described in Section III,
Quarterly Inspection. Replace if necessary.
Heating element not working on
all phases
Check to see that heating element is
working on all phases, by checking the
resistance (ohms) value for each element
and comparing with the chart included in
Section VI.
Water temperature
below settings at all
times
Heater improperly sized Verify heater is properly sized for the flow
rate and temperature rise of your system.
See formulas included in Section VI.
Replace elements with proper size as
necessary.
Relief valve
discharges
continuously
Excessive temperature or
pressure in tank
Temperature and pressure relief valves are
made to operate if the water temperature
exceeds 210°F or water pressure exceeds
the pressure rating of the safety relief valve.
If trouble is excessive temperature, then
thermostat is not shutting off at the right
setting and thermostat must be replaced.